CALYS 150 – AOIP Advance Documenting Multifunction Calibrator Thermometer

10$

Model: CALYS 150

 

CALYS 150 field documenting multifunction calibrator is the top instrument of the range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process, pressure and frequency in one single instrument.

 

Please refer to product’s datasheet (PDF)

 

Product Dimensions (mm): 210 x 110 x 50

Sale

CALYS 1500 – AOIP Advanced Laboratory Electrical Calibrator / Dual Input Thermometer

10$

Model: CALYS 1500

 

CALYS 1500, most advanced and accurate laboratory electrical calibrator of the range, does not only work as a simulator (IN / OUT) but also as a dual channel thermometer (IN / IN) to perform comparison calibration. It calibrates HART transmitters (HART communicator) and thermistors.

 

Please refer to product’s datasheet (PDF)

 

Product Dimensions (mm): 340 x 320 x 160

Sale

CALYS 50 – AOIP Field Multifunction Calibrator for Basic Use

10$

Model: CALYS 50

 

CALYS 50 is a basic multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process and frequency in one single instrument.

 

Please refer to product’s datasheet (PDF)

 

Product Dimensions (mm): 210 x 110 x 50

Center 32, Sound Level Meter (IEC 61672-1 class 2, Economy)

FEATURES

  • 60dB Dynamic Space In Each Range
  • Time Weighting Fast/Slow
  • Frequency Weighting A/C
  • Max/Min Function
  • Complies With IEC 61672-1 Class 2 Standard

 

SPECIFICATIONS

  • Measurement Range: 30~130dB
  • Level Range: 30~90dB, 50~110dB, 70~130dB
  • Accuracy: ±1.4dB (ref. 94dB@1KHz)
  • Frequency Weighting: A / C
  • Time Weighting: Fast, Slow
  • Frequency Range: 20Hz to 8KHz
  • Microphone: ½ inch Electret condenser microphone
  • Auxiliary Outputs: AC/DC Output
  • Battery: 9V battery
  • Dimensions: 258x55x25 mm
  • Weight: Approx.185g

 

Please refer to the product’s datasheet here. (pdf)

CENTER 337, Light Meter

FEATURES

  •  3 3/4 Digits Display
  • Auto Ranging
  • Automatic Power Off
  • Fc / lx Function Selectable
  • Hold Function
  • Range Display
  • Automatic Zero When Power On

 

SPECIFICATIONS

  • Light Range: 0.000~4000 fc ;  0.00~40000 lx
  • Resolution: 0.01~10 Lx;  0.001~1 fc
  • Accuracy: ±3%rdg, ±5dgts
  • Sample Rate: 2 times/sec
  • Auto Power Off: 30 minutes
  • Battery: 9V battery
  • Dimensions: 196x54x34 mm
  • Weight: Approx.180g

CENTER 390, Datalogger Sound Level Meter (IEC 61672-1 class 2)

FEATURES
  • Complies With IEC 61672-1 Class 2 Standard
  • 32Resolution 0.1 dB

SPECIFICATION

  • Level Range: 30~130dB
  • Accuracy: ±1.4dB (ref. 94dB@1KHz)
  • Frequency Weighting: A / C
  • Time Weighting: Fast, Slow
  • Frequency Range: 20Hz to 8KHz
  • Microphone: ½ inch Electret condenser microphone
  • Auxiliary Outputs: AC/DC Output
  • Battery: 1.5V AA size battery x 4
  • Dimensions: 272x83x42 mm
  • Weight: Approx.390g

 

 

Please refer to the product’s datasheet here. (pdf)

CENTER 530, Light Meter

FEATURES

  •  3 1/2 Digits, 1999 Count LCD
  • Fc / lx Function Selectable
  • Data Hold Function
  • Range Display
  • Big LCD Display
  • Automatic Zero When Power On
  • Detachable & Rotatable Light Sensor

 

SPECIFICTIONS

  • Light Range: 0.0~19990 fc ;  0.0~199900 lx
  • Resolution: 0.1 Lx ;  0.1 fc
  • Accuracy: ±3%rdg, ±5dgts
  • Sample Rate: 2 times/sec
  • Auto Power Off: 30 minutes
  • Battery: Size AA battery x 2
  • Dimensions: 169x63x37 mm
  • Weight: Approx.210g

CO 112, Kimo CO Sensor / Transmitter

CO2 sensors allow you to measure carbon dioxide.

Kimo’s CO 112 measures CO2 from 0 to 5,000 ppm.

 

  • Measuring range from 0 to 5,000 ppm
  • With or without 10-digits LCD display
  • Software or DIP switch configuration
  • 0-10 V or 4-20 mA output
  • Housing with simplified mounting system
  • Quick and easy mounting with the 1/4 turn system with wall-mount plate

 

Please refer to the product’s datasheet here. (pdf)

CO 50, Kimo CO Meter

The Kimo CO 50 is a portable, handheld carbon monoxide (CO) meter with a 2-line display that allows you to easily measure carbon monoxide content in ambient air. Carbon monoxide can be a silent killer.

 

  • Measuring range CO: 0 to 500 ppm Temperature: -20 to +80°C
  • Hold function
  • Auto shut-off after 20 mins
  • Easy to use
  • Built-in-probe
  • Adjustment certificate

 

Please refer to the product’s datasheet here. (pdf)

Sale

CP 6632 – AOIP Handheld Process Signal Calibrator

10$

Model: CP 6632

 

CP 6632 is a handheld accurate process signal calibrator (150 ppm reading accuracy) that measures or generates process current and voltage. Robust and easy-to-use, this instrument has been designed to make maintenance operations easier on sensors and transmitters using process signals such as 4-20 mA or 0-10 V.

 

Please refer to product’s datasheet (PDF)

 

Product Dimensions (mm): 157 x 85 x 45

CTV210-R, KIMO Air velocity and temperature sensor

Kimo’s CTV 210-R is a transmitter with hotwire probe measuring air velocity from 0 to 30 m/s and temperature from 0 to +50°C.

Measure prarameter: Air Velocity & Temperature

 

FEATURES

  • Measuring ranges: air velocity: from 0 to 30 m/s
  • Temperature : 0 à +50 °C
  • With or without 2-line 19-digits LCD display
  • Two relays
  • 0-5/10 V or 0/4-20 mA outputs
  • Adjustment certificate

 

Please refer to product’s datasheet (PDF)

DBM 620, KIMO Air Flow Meter

Kimo DBM 620 Air Flow Meter is a multipurpose electronic air balancing instrument primarily used for efficiently taking direct air volume readings from air vents.

 

FEATURES

  • Simultaneous display of up to 4 parameters. Choose between airflow, humidity, atmospheric pressure, temperature, differential pressure and air velocity
  • Simultaneous display of air flow and temperature, automatic airflow direction (extraction or air blast)
  • Automatic averaging or point by point averaging, HOLD function
  • Removable measuring unit (micromanometer function)
  • Display on smartphone or tablet by Bluetooth connection
  • Standard accessories: 610 x 610mm hood with flow straightener and flodable frame, 2 x 0.80 m of silicone tube, 1 Removable measuring unit with Bluetooth® connection, 1 Base including the measurement grid and a temperature and hygrometry probe, a transport case and a calibration cert.

 

Available Hoods
DBM 620 air flow meter comes in standard with a 610 x 610mm hood. 4 other hoods are available as options:
• 1020 x 1020 mm
• 720 x 720 mm
• 720 x 1320 mm
• 420 x 1520 mm

 

MEASURING RANGES

  • Portata (parametro calcolato) :  35.00 m³/h … 4250.00 m³/h
  • Velocità (parametro calcolato) : 0.20 m/s … 10.00 m/s
  • Temperatura (NTC) :  -20.00 °C … 70.00 °C
  • Umidità relativa (sensore capacitivo) : 0.00 % RH … 100.00 % RH
  • Pressione atmosferica  :  700.00 hPa … 1100.00 hPa
  • Pression  :  -2500.00 Pa … 2500.00 Pa

The DBM 620 Air Flow Meter comes equipped with the SmartKap mobile app. You can use SmartKap to connect to your DBM 620 via the Bluetooth® protocol, allowing you to configure the device, as well as visualize and save its measurements.

 

Please refer to the product’s datasheet (pdf).

DewMaster Chilled Mirror Hygrometer

A fast, multi-function, high precision chilled mirror hygrometer for continuously monitoring the dew/frost point temperature, parts per million water vapor by volume or percent relative humidity in gas streams.

The DewMaster is a laboratory grade, high precision, field proven instrument with multiple available sensor configurations and wide applicability to fit all budgets.

 

  • Measurement Ranges and PPMv Ranges:
    0 to 100% RH with all sensors, non-condensing conditions
    0 to 999,999 PPMv with all sensors, non-condensing conditions

 

  • Accuracy:
    ±0.2°C (0.36°F) dew/frost point standard
    ±0.1°C (0.18°F) dew/frost point optional
    ±0.5% of full scale pressure

 

  • Air Temperature Sensor Range:
    -100 to 250°C (-148 to 482°F)
    ±0.1°C accuracy

 

Please refer to product’s datasheet (PDF)

 

Differential pressure transmitter 692

The pressure transmitter of type 692 with proven, unique ceramic technology, features adjusted and amplified sensor signals which are available as standardised voltage or current outputs. Various application-specific pressure and electrical connections and housing materials suitable for different media can be provided.

 

FEATURES

  • Very low temperature sensitivity
  • High resistance to extreme temperatures
  • No mechanical creepage
  • Modular system and choice of materials to suit individual applications

 

SPECIFICATIONS

  • Medium : Liquids and gases
  • Pressure range : 0…0.1 – 25 bar
  • Output : 0…5V, 0…10V, 4…20mA
  • Accuracy : <0.5% fs
  • Electrical connection : Cable 1.5m, connector DIN EN 175301-803-A, connector DIN EN 60130-9
  • Pressure connection : Hose connection or screw fitting, outside thread, adapter inside and outside thread
  • Mounting bracket for screw mounting

 

Please refer to the product’s datasheet here. (pdf)

Differential pressure transmitter 699

These pressure transmitters type 699 are available in switchable pressure ranges and with digital device or Modbus. The full-version includes customer specific adjustment possibilities. Especially  developed sensors for each pressure range allow a physically correct and long term stable measurement.
The large variety offers a manifold use in the air-conditioning technique as well as for fine measurement in industry or medical applications.

 

FEATURES

  • Available with or without LCD display
  • Adjustable measurement range
  • Switchable output signals
  • Switchable response curve (linear or root-extracted)
  • Full scale adjustable
  • Application at over and low pressure range possible
  • Fast, easy mounting. Housing incorporates integral bracket for wall or ceiling mouting
  • Resettable Zero Point (Reset button)

 

SPECIFICATIONS

  • Medium : Air and neutral gases
  • Pressure range : -1…1 mbar / 0…0.3 – 50 mbar
  • Output : 0…10V, 0…20 mA, 4…20 mA
  • Accuracy : <0.5% fs
  • Electrical connection : Screw terminals
  • Pressure connection : Hose connector Ø 6.2mm
  • Screw mounting

 

Please refer to the product’s datasheet here. (pdf)

DMT143 & DMT143L (Long) – Miniature Dew Point Transmitters

Model: DMT143 & DMT143L (Long)

for OEM applications

 

Miniature size dew point transmitters DMT143 and DMT143L are ideal choices when you want to measure dew point accurately in small compressed air dryers, plastic dryers, additive manufacturing and other OEM applications. They are easy to integrate and can be used in Vaisala handheld meter DM70. The long version has replaced the DMT242.

Features
  • Vaisala DRYCAP® technology with auto-calibration
  • Fast response time
  • Dew point measurement range -70 … +60 °C (-94 … +140 °F)
  • Accuracy ±2 ºC (±3.6 ºF)
  • Withstands condensation
  • Compatible with Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70
  • Traceable calibration (certificate included)
  • LED alarm for exceeded dew point level

 

Key benefits

  • Convenient size – Miniature size dew point probes eg. small industrial dryer application.
  • Low  maintenance costs – Stable measurement enables long calibration intervals saving maintenance cost.
  • Easy to use – Analog output options, easy servicing and date transfer. Compatible with handheld meter DM70.

 

Please refer to product’s datasheet (PDF)