MFC5150x – Meriam Intrinsically Safe, HART Communicator

Model: MFC 5150X

 

Handheld calibrators and filed communicators. Available in ATEX (intrinsically safe) and Non-ATEX models, the MFC5150 directly reads Device Descriptions with Free upgrades/downloads for life the product – no subscriptions!

 

  • The MFC5150 is built on the SDC-625 infrastructure and runs Windows CE
  • With a 1 GHz processor and an 4 GB Micro SD card, this HART® communicator is ideal for all
    of your data storage needs
  • The 4.3 inch touchscreen provides excellent anti-glare viewing, allowing for comfortable
    mobile use in darkness or in bright sunlight
  • All functions are easily navigated via the full QWERTY keyboard and intuitive icons similar
    to that of a smart phone.
  • Features hyperlink menu paths, teachable device specific shortcuts, instant on, multiple languages,
    help context, video’s and TAB access to panes just like on a computer.
  • The MFC5150x is certified in the following Hazardous locations : Class I, Division I Group IIC
    (US/Canada), ATEX Zone 0 Group IIC (Europe), IECex Zone 0 Group IIC (Asia, South America, Africa)

 

Please refer to product’s datasheet (PDF)

 

 

MFT 4010 – Meriam Modular Calibrator with HART® Communicator

Model : MFT 4010

 

All-in-One tool. Takes the place of multiple handheld instruments, simplifies workload and improves productivity

 

  • Multifunctional tester: Modular Calibrator, HART Communication, Documentation with Meriam’s DMS Database Software
  • Calibration types supported: Pressure, T/C, RTD, I/P, P/I, Switch, Loop and mA/V for conventional or HART transmitter or local indicators
  • Device Specific HART commands for smart Analytic, Flow, Level, Pressure, Temperature & Valve devices
  • Three sensor bays for a variety of pressure, temperature and electrical measurement and simulation Sensor Modules
  • Intrinsically Safe option
  • Accuracy: ±0.025%FS traceable to NIST with full temperature compensation from -5 to 50°C

 

Modules Available

  • Thermocouple Measurement and Simulation
  • Pressure Module
  • RTD Measurement and Simulation
  • Voltage, Current & Simulate and 24V DC Isolated Loop Power

 

 

Please refer to product’s datasheet (PDF)

 

Sale

MGC – Multi Gas Clip Detector

10$

Model: MGC

Day in, day out, your workers have to charge their portable multi gas detectors so they can keep testing for the presence of hydrogen sulfide (H2S), carbon monoxide (CO), oxygen (O2) and combustible gases (LEL). Unfortunately, sometimes they may forget to do so. Gas Clip Technologies can help prevent this safety risk with our new Multi Gas Clip (MGC).

The new MGC can go a full 2 months without a charge, even without ever having to be turned off. Shut down the detector nightly and the battery can last up to 4 months.

 

 

Please refer to product’s datasheet (PDF)

 

Sale

MGC-IR Pump, Multi Gas Clip Pump IR

10$

Model: MGC Pump

Combustible gases, H2S , CO, and O2

Please refer to product’s datasheet (PDF)

 

Sale

MGC-S, Multi Gas Detector Simple

10$

Model: MGC SimpleDetects H2S, CO, O2 & combustible gases (LEL)

No charging ever! No calibration needed!

Save time never having to charge or service your portable multi-gas detector! Reliably test for H2SCOO2 & combustible gases (LEL) with this simple-to-use & simple-to-maintain detector. Just turn it on & have worry free assurance of protection against toxic gases 24/7 for two full years.

Gas Clip Technologies’ continued development and refinement of advanced low-power photometric infrared technology for LEL measurement helps make gas detection simpler than ever in the newest member of their gas detector family – the Multi Gas Clip Simple.

 

Please download the datasheet here. (pdf)

MGF16BN – Meriam Digital Pressure Gauge (Medical)

The MGF16BN digital pressure gauge is designed to handle the demands of pressure measurement. Pressure ranges are available to 5 000 PSIG at standard accuracy of ± 0.25 % of full scale or higher accuracy of ± 0.1 % of full scale.

 

The display is a 4 digit LCD with 0.5″ high numerals and a lower alphanumeric display for engineering units to aid in set up. Each gauge includes up to 15 selectable engineering units depending on the sensor range. The gauge is powered by two AA alkaline batteries.

 

  • ±0.25% Test Gauge Accuracy
  • 316L Stainless Steel Wetted Parts
  • NEMA 4X
  • Capture Minimum and Maximum Readings
  • Push Button Zero
  • Selectable Engineering Units
  • Selectable Auto Shutoff Times

 

Please refer to product’s datasheet (PDF)

Sale

MH-10KT Hydraulic Pressure Kit / Pump

10$

Model: MH10-KT Hydraulic Calibration Pump Kit, 0 to 10,000 PSIG Range

 

Wide Pressure Range

  • 0 – 10,000 psi (700 Bar)
  • Compatible with most hydraulic fluids, oils and water
  • Connections (2 ports) 1/4 inch NPT/BSP

 

Please refer to product’s datasheet here. (PDF)

MicroK, Isotech Precision Thermometry Bridge

Model: MicroK

 

The microK family of precision thermometry bridges use a completely new measurement technique to achieve accuracies to better than 0.02ppm.

 

  • Supports SPRTs, IPRTs, Thermistors and Thermocouples
  • High accuracy thermocouple measurements with a voltage uncertainty of <0.25μV
  • Can display in °C, °F, K, ratio, resistance, voltage with numeric and graphical display
    modes
  • Simple Touch Screen operation with easy to use interface and data logging options
  • Can connect USB Memory Stick, Keyboard, Mouse
  • No PC needed, the display can show temperature and resistance in addition to ratio

 

Please refer to product’s datasheet (PDF)

MilliK, ISOTECH Precision Thermometer

Model: MilliK

 

A high accuracy measurement and calibration of Platinum Resistance Thermometers, Thermistors, Thermocouple and Process Instrumentation (4-20mA) over the range -270°C to 1820°C

 

  • Has two input channels for sensors and a third channel for current
  • The milliK can control Isotech temperature sources, sequencing through
    a programmable list of temperature set points and log data to internal memory or
    a USB drive.
  • Can display in °C, °F, K, Ohms, mV and mA with numeric and graphical display modes
  • High Accuracy < ±5ppm for PRTs, ±2μV for Thermocouples and ±1μA Transmitters

 

Please refer to product’s datasheet (PDF)

 

MODEL 2212, Handheld Indoor Air Quality Monitor

The Kanomax Indoor Air Quality Monitor – Model 2212 simplifies the labor involved and eliminates the need to purchase and learn multiple instruments. It simultaneously measures multiple parameters such as: CO, CO2, Temperature, and Relative Humidity. It is capable of calculating Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and % Outside Air. Calibration is easy and can be done by the user.

The monitor can also check CO2 levels and determine the rate of exchange, or the % of outside air, being introduced to a building per ASHRAE standard 62. It is capable of examining a building’s IAQ conditions to optimize worker productivity and features quick start-up and high accuracy in measuring CO2 and CO concentration levels in the environment.

 

  • Simultaneously measures multiple parameters such as: CO, CO2, Temperature, RH, to monitor IAQ
  • Calculates Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and % Outside Air
  • Simplifies the labor involved and eliminates the need to purchase and learn multiple instruments
  • Easy user self-calibration
  • The monitor can also check CO2 levels and determine the rate of exchange, or the % of outside air, being introduced to a building per ASHRAE standard 62
  • Examines building IAQ conditions to optimize worker productivity
  • NIST Traceable Calibration Certificate*
  • Features quick start-up and high accuracy in measuring CO2 and CO concentration levels in the environment
  • Sampling function records multiple point measurements

Please refer to the product’s datasheet here. (pdf)

Model 6710, TABMASTER Airflow Capture Hood

Whether you need to test a newly installed HVAC system for initial functionality, re-test a building’s HVAC after it undergoes significant constructional changes, or regular seasonal change check-ups, the TABmaster Flow Hood Model 6710 needs to be in your equipment arsenal.

The unit has some defining characteristics that put it into the running for best choice among professionals who actually operate TAB instruments in the field on a day-to-day basis.

 

  • 23 to 2500 CFM (40 to 4250 m3/h) range
  • Simultaneously measures and displays air flow, temperature and humidity
  • Displays the direction of the airflow as well as the velocity
  • Store up to 3,000 measurements
  • Advanced storage feature allows you to store multiple measurements under a single ID number
  • This is the perfect tool for accurate supply and return airflow measurements
  • Our optional interchangeable hoods make it a snap to sample the air for any duct size
  • The unit is lightweight and easy to handle
  • Simultaneously measures and displays air flow, temperature and humidity
  • Motorized tilt on meter to allow for meter angle adjustment
  • A multi-functional instrument that measures airflow and pressure readings
  • Air volumetric flow measurements through registers, diffusers and grilles
  • Displays Air velocity direction and measurement in full color for clear, easy viewing
  • HERS (Home Energy Rating System) approved testing instrument

 

Please refer to the product’s datasheet here. (pdf)

Model 989, Isotech Black Body Source

Model: Black Body Source, 989

It was used to increase the accuracy of thermal imagers measuring human skin temperature in temperature screening of applications. It can also be used to check non-contact clinical thermometers. The upgraded controller can either be locked to a single temperature or it can be adjusted over a new wider temperature range of 20°C to 50°C. Model 989 also has a PC
interface fitted as standard. It allows the temperature to be both monitored and adjusted from a PC.

 

 

Please refer to product’s datasheet (PDF)

 

  • Improves accuracy of Fever Detection Systems
  • Covers 20°C to 50°C with Fast Thermal Response
  • Check Non-Contact Thermometers
  • The blackbody can maintain its set point in high ambient temperature conditions and it can also operate below the ambient temperature